CCTCS - RUBBER AND SHELLAC BONDED ABRASIVE PRODUCTS

  • MSDS: CCTCS
  • Manufacturer: NORTON CO
  • Product Name: RUBBER AND SHELLAC BONDED ABRASIVE PRODUCTS
  • National Stock Number: 5350-00N063107
Product Identification

Product ID:RUBBER AND SHELLAC BONDED ABRASIVE PRODUCTS
MSDS Date:03/12/1996
FSC:5350
NIIN:00N063107
MSDS Number: CCTCS

Responsible Party
NORTON CO
1 NEW BOND ST
WORCESTER, MA 01615
US

Emergency Phone: 508-795-5000

Info Phone: 508-795-5000

Cage: 44197

Contractor
NORTON CO
15008 WORCESTER, MA 01606-0008 US

Telephone: 508-795-2690/508-795-5000

Cage: 44197

Ingredients

ZIRCONIUM OXIDE

CAS: 1314-23-4

RTECS: ZH8800000

Fraction By Weight: 30-50%

OSHA PEL 5 MG/M3 (MFR)

ACGIH TLV: 5 MG/M3 (MFR)


3); (ALUMINUM OXIDE) (SARA 313)

CAS: 1344-28-1

RTECS: BD1200000

Fraction By Weight: 40-90%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


0.003-10.00

CAS: 65997-17-3

Fraction By Weight: >0.01%

OSHA PEL 5 MG/M3 RESP DUST

ACGIH TLV: 10 MG/M3 (<7MICRONS)


SILICON CARBIDE

CAS: 409-21-2

RTECS: VW0450000

Fraction By Weight: 80-90%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


SILICA, CRYSTALLINE - QUARTZ; (CRYSTALLINE SILICA, QUARTZ)

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: 0.001-1%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 5-11%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


PHTHALIC ACID, DIBUTYL ESTER; (DIBUTYL PHTHALATE) (SARA

CAS: 84-74-2

RTECS: TI0875000

Fraction By Weight: 0.010-1%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


DISULFIDE, BIS(DIMETHYLTHIOCARBAMOYL);

CAS: 137-26-8

RTECS: JO1400000

Fraction By Weight: 0.010-1%

OSHA PEL 5 MG/M3

ACGIH TLV: 1 MG/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


SILICA, AMORPHOUS, PRECIPITATED AND GEL; (AMORPHOUS SILICA,

CAS: 112926-00-8

RTECS: VV7315000

Fraction By Weight: 0.010-2%

OSHA PEL 6 MG/M3 (MFR)

ACGIH TLV: 10 MG/M3 (MFR)


FLUORIDES

Fraction By Weight: 2-10%

OSHA PEL 2.5 MG/M3 (MFR)

ACGIH TLV: 2.5 MG/M3 (MFR)


USE SFTY GUARD COVERING AT LEAST 1/2 OF

RTECS: 9999999ZZ


OPERATING SPEED, W/GUARD IN PLACE, FOR AT LEAST 1

RTECS: 9999999ZZ


STOPPING WHEEL TO AVOID CREATING AN OUT-OF-BALANCE

RTECS: 9999999ZZ


CRYSTALLINE SILICA DID NOT PRDCE ANY DETECTABLE AMT

RTECS: 9999999ZZ


BE COMPRISED OF ONLY SOME OF THE HAZARDOUS

RTECS: 9999999ZZ


SHOULD BE WORN WHERE REQUIRED (SEE OSHA 29

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:DUST MAY BE SLIGHTLY
IRRITATING TO EYES AND RESPIRATORY TRACT AT HIGH CONCENTRATIONS.
EYE CONTACT:DUST MAY IRRITATE EYES. SKIN CONTACT:SOME MAY
EXPERIENCE SKIN IRRITATION FROM DUST. I NGESTION:NO KNOWN ADVERSE
EFFECTS, BUT INGESTION NOT RECOMMENDED. CHRONIC:INHALATION:MAY
AFFECT BREATHING CAPACITY.
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC
MONOGRAPHS, SUPP, VOL 7, PG 341, 1987:GROUP 2A. NTP 7TH ANNUAL RPT
ON CARCINS., (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION:REMOVE TO FRESH AIR. IF BREATHING HAS STOPPED,
GIVE ARTIFICIAL RESPIRATION. GET MEDICAL ATTENTION IMMEDIATELY.
SKIN CONTACT:WASH AFFECTED AREA WITH SOAP AND WATER. OBTAIN MEDICAL
ASSISTANCE . EYE CONTACT:WASH WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES. OBTAIN FIRST AID AND MEDICAL ASSISTANCE, IF
NEEDED. INGESTION:CALL POISON CONTROL CENTER, HOSPITAL EMER ROOM OR
MD IMMED.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NOT APPLICABLE.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:FOLLOW NORMAL CLEAN UP PROCEDURES. ECOLOGICAL
INFORMATION: CHEMICAL FATE:RESIN BONDED MATERIALS DEMONSTRATE
SIMILAR DEGRADATION RATES AS PHENOLIC PLASTICS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:ALWAYS HANDLE AND STORE WHEELS IN A
CAREFUL MANNER. ALWAYS VISUALLY INSPECT ALL WHEELS BEFORE MOUNTING.
Other Precautions:ALWAYS CHECK MACHINE SPEED AGAINST ESTABLISHED MAX
SAFE OPERATING SPEED MARKED ON WHEEL. ALWAYS CHECK MOUNTING FLANGES
FOR EQUAL & CORRECT DIAMETER. ALWAYS USE MOUNTING BLOTTERS. ALWAYS
BE SURE WORK R EST IS PROPERLY ADJUSTED. ALWAYS(ING 11)

Exposure Controls

Respiratory Protection:NIOSH APPROVED RESPIRATORS ARE REQUIRED WHEN
AIRBORNE CONTAMINANT LEVELS EXCEED THE TLV(S).
Ventilation:HANDLE WITH ADEQUATE VENTILATION. SEE OSHA 29 CFR 1910.94
(VENTILATION) AND 29 CFR 1910.1000 (AIR CONTAMINANTS).
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
USE OF PROD MAY CREATE ELEVATED SOUND LEVELS. HEARING PROT (ING 16)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PRODS:SIGNIFICANTLY GREATER THAN GRINDING WHEEL COMPONENTS.
COOLANTS MAY PRDCE OTHER DECOMP PRODS. EXPLAN OF CARCIN:1994:ANTIC
TO BE CARCIN. ANIMAL:LUNG. CARBON BLACK:IARC MONOGRAPHS ON EVA L OF
CARCIN RISK OF CHEMS TO MAN, VOL 65, PG 24-27, 1995:GROUP 2B.

Chemical Properties

Appearance and Odor:SOLID ARTICLE; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN USE, DUST & DECOMPOSING ODORS MAY
BE GENERATED. IN MOST CASES, MATL REMOVED FROM WORKPLACE WILL BE
(SUPP DATA)

Disposal

Waste Disposal Methods:FOLLOW LANDFILL METHODS CONSISTENT WITH
APPLICABLE FEDERAL, STATE AND LOCAL LAWS. PRODUCTS LISTED WITH
FLUORIDES MAY HAVE A SLIGHLY SOLUBLE FLUORIDE SWARF.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.